DECTRO 500-PB1-MCX
A device of detection MULTI-SENSORS adapted to pump and mixed pump for concrete
Multi-sensors is an evolution from device DECTRO 500-PB1 to a hybrid solution with several sensors on the boom.
Sensors of detection MCx
System of prevention which, with one sensor by boom positionned in the end of every boom permitte an omnidirectional detection in proximity. Every sensor, in telegraphic link , indicate presence of a "high voltage" electric line in the environement of a boom which is concerned with all of boom movements (pumping is still authorized). Forced-function permitte to get going again with an audible beep when there is a boom movement.
Threshold of detection
DANGER: threshold of detection signalled by visual and audible alarms - blocking of the boom.
Every sensor is adjusted for a distance of detection from 6 to 9m according to lenght of the boom compare with a 20kV line.
Threshold of detection adjustable at installation
Threshold detection is adjusted in factory and can be it on site during assembling. Thus, its possible to fix the volume of protection (distance of detection) according to use.
Visualization in outside
- A box of visualization in outside is situated in the environement of pump. It can integrate Forced Function.
Assembling on any kind of pump
Options: - possibility to add a flashing light or to connect an existing flashing light to signal a presence of Danger in the vehicle environement.
- Kit "Carried Alarm": permitte to deport wireless near gas pump attendant , audible informations about presence of Danger and Forced Function starting.
Remark: this version doesn't have visualization of alarms in cabins. Possibility to upgrade volumetrics versions